The Secure Power Switch G2 Master is an enhanced power distribution and control unit that enables remote power management of 8 devices (extendable up to 136) over the Internet. This high security device supports the SSL protocol and also includes IP device and environmental monitoring functionalities. It supports the HTTP, HTTPS, DHCP, Syslog, SNMP, SMTP and SNTP protocols.
An internal clock allows to timestamp the syslog messages, e-mails and internal logs, and can be used to trigger time-controlled actions.
Remote Power Management
Each power outlet can be turned On/Off or restarted over IP.The number of controlled outlets can be extended up to 136 by cascading 16 Satellite units (PSE518SA).
Two separate AC Power Inputs
To improve the security and increase the total current load, the Secure Power Switch Master supports dual power inputs (up to 10 Amps each). The first one provides power for outlets 1 to 4 and the second one for outlets 5 to 8. This feature is ideal for power management of servers with redundant power supplies.
Power Outlet Extension
Up to 16 Secure Power Switch Satellites (PSE518SA) can be connected to a Master to control up to 136 power outlets.
Power Outlet Grouping
Groups of outlets from the Master and any Satellites can be created to control multiple power supply servers and many devices with a single command.
Sequential power up/down
Avoids the risk for a power inrush to blow a fuse or circuit breaker in the data centre.
Programmable restart and Power-up delays
The restart delay (1-65535 s) and the power-up delay (0-3600 s) can be set individually for each power outlet.
Access and accounts
The administrator password allows complete configuration and control of all power outlets. The administrator can create up to 255 user accounts with restricted rights.
Multiple concurrent users
255 users can have a concurrent access to the Master and all Satellites and control their designated power outlets.
Advanced Security
For your security, account access and data transfer can be encrypted with SSL technology.
DHCP Client
The DHCP option enables to simplify the network configuration management.
Scheduler for Time-Controlled Applications
This time-controlled function is used to schedule actions according to a defined time table. It lets you control power outlets and dry contacts and allows to send Emails.
IP Device Monitoring
This function lets you monitor IP devices using PING and/or Scan functions with automatic reboot in case of lock-up of the monitored device.
Temperature and Humidity Monitoring
This function lets you monitor temperature and humidity in racks or server rooms. If thresholds are exceeded, power outlets and dry contacts can be automatically controlled and Email / Syslog messages / SNMP traps sent.
Dry contacts monitoring
The I/O Extension Module with 8 inputs for dry contacts let you monitor magnetic door contacts, smoke or water detectors.
Improved log file reporting
Event logs are written to the internal log file and can be sent to a primary and a secondary Syslog Server and to an Email address.
Programmable Labels
A 32-character label can be attributed to the Power Switch and to each power outlet to avoid confusion during operation.
Easy Configuration
Full configuration can be performed through the Web using http or https. The network settings can also be done via a convenient tool or a Terminal connection.
Connections —
Power inputs: (2) IEC-320 C14
Power outputs: (8) IEC-320 C13
Network: (1) RJ-45 F 10/100 Mbps Ethernet
Serial: (1) DB-9 F RS-232
Engine —
Nominal input voltage: 230 V/50Hz
Output voltage: 230 V/50Hz
Maximum total current: 2 X 10A
Maximum current / outlet: 10 A
Network standards: IEEE 802.3, 10/100BASE-T
Network protocols: TCP/IP, HTTP, HTTPS
Network connection: RJ-45 for UTP CAT5
Max. network cable length: 100 m (not included)
SSL technology: Version 2 and 3
Management —
Indicators: (1) power supply A, (1) power supply B, (1) network traffic, (8) socket status, (4) dry contacts output status
Physical and environmental —
Operating temperature: 0°C to +40°C
Operating humidity: 10% to 80%
Dimensions: 437 x 107 x 42 mm
Weight: 2 kg